Performance Test
SAFETEPPerformance Test
SAFETEP has been proven by technology competitiveness and experiment.
It has the excellent wear resistance property with an aluminum base and can be used semipermanently. Test results of wear resistance performance and excellent slip resistance show high performance from a resistance test results in the rain and snow.
Evaluation Method | Unit | Performance Standard | Test Result | Pass or Fail |
---|---|---|---|---|
ASTMD 4060: 2007 | mg | 40 or less | 7 | Pass |
KSF 2375:2001 | BPN | 40 or less | 66 | Pass |
Performance Test of a Luminescent Side (Unit: mcd / ㎡)
It is a test result that maximized the inducement function such as evacuation by outstanding luminescent performance than the standard. It shows the effect for long time by constant absorption of light.
Test Item | Criteria | Unit | Performance Standard | Test Result | Pass or Fail |
---|---|---|---|---|---|
Luminance Test | 5 minutes | mcd/m² | 110 or more | 119 | Pass |
10 minutes | mcd/m² | 50 or more | 111 | ||
20 minutes | mcd/m² | 24 or more | 59 | ||
60 minutes | mcd/m² | 7 or more | 18 |
* Test criteria : performance standard tested by the luminescent inducement sign and performance technology standard.